SikaProof® P-12
FPO self adhesive sheet membrane for post-applied fully bonded below ground waterproofing
SikaProof® P-12 is a flexible polyolefin (FPO) self-adhesive sheet membrane for post-applied fully bonded below ground waterproofing of existing reinforced concrete structures. Membrane thickness 1.2 mm. SikaProof® P-12 is pre-coated with an adhesive sealant layer and is cold applied onto primed concrete structures by a simple peel and stick process by using SikaProof® Primer-01 as a system primer.
- Post-self-adhered, fully bonded on existing concrete structures
- No lateral water underflow between the concrete structure and the membrane system
- High flexibility and crack-bridging properties
- Validated high watertightness
- Easy to install with fully adhered joints (no welding required)
- Cold applied (no heat or open flames)
- Temporarily resistant to weathering and UV-light during construction
- Highly durable and resistant to aging
- Resistant to aggressive elements in natural ground water and soil
- Can be combined with other approved Sika Waterproofing / Joint Sealing Systems
Usage
Damp-proofing, waterproofing and concrete protection for basements and other below ground structures against ground water ingress. Suitable for use on:- Horizontal reinforced concrete slabs, decks and podiums
- Vertical reinforced concrete walls
- Extensions and reconstruction works
- Prefabricated structures
Advantages
- Post-self-adhered, fully bonded on existing concrete structures
- No lateral water underflow between the concrete structure and the membrane system
- High flexibility and crack-bridging properties
- Validated high watertightness
- Easy to install with fully adhered joints (no welding required)
- Cold applied (no heat or open flames)
- Temporarily resistant to weathering and UV-light during construction
- Highly durable and resistant to aging
- Resistant to aggressive elements in natural ground water and soil
- Can be combined with other approved Sika Waterproofing / Joint Sealing Systems
Packaging
Rolls wrapped individually in a yellow PE-film.
Roll width | Roll length |
1.00 m | 20 m |
Colour
Light yellow sheet membrane with a white release film on the adhesive side.
Product Details
ENVIRONMENTAL INFORMATION
- BRE Environmental Product Declaration (EPD) available
APPROVALS / STANDARDS
- CE Marking and Declaration of Performance to EN 13967 - Flexible sheets for waterproofing – Damp proofing and basement tanking
- Agrement Certificate, SikaProof® P,BBA,Certificate No.13-5075
- Test Report, Functionality, SikaProof P-12, WISSBAU, No. 2013-253
- abP Approval, SikaProof P-12, Report No. MPANRW-2211463-1
Chemical Base
Membrane Layer: | Flexible Polyolefin (FPO) |
Sealant/adhesive: | Polyolefin (PO) |
Shelf Life
12 months from date of production
Storage Conditions
Product must be stored in original unopened and undamaged sealed packaging in dry conditions and temperatures between + 5 °C and + 30 °C. Store in a horizontal position. Do not stack pallets of the rolls on top of each other, or under pallets of any other materials during transport or storage. Always refer to packaging.
Effective Thickness
Total Thickness (= deff) | 1.20 mm (-5 /+10 %) |
Membrane Thickness | 0.60 mm |
Mass per Unit Area
1.20 kg/m2 | (-5 /+10%) |
System Structure
The following system components must be used:
- SikaProof® P-12 sheet membrane
- SikaProof® Primer-01
Ancillary products:
- Accessories and complementary products are available to provide detailing and connection solutions.
Resistance to Impact
≥ 200 mm | [EN 12691, Method A] |
Resistance to Static Load
≥ 20 kg | [EN 12730, Method B] |
Resistance to Root Penetration
Pass | [CEN/TS 14416] |
Tensile Strength
Machine direction: | ≥ 6,0 N/mm2 |
Cross direction: | ≥ 6,0 N/mm2 |
Elongation
Machine direction: | ≥ 350 % |
Cross direction: | ≥ 350 % |
Crack Bridging Ability
Class A 5, no cracks | (DIN EN 1062-7) |
Adhesion in Peel
≥ 100 N/50mm (on primed concrete) | [EN 1372] |
Resistance to Tearing (nail shank)
Machine direction: | ≥ 200 N |
Cross direction: | ≥ 200 N |
Joint Shear Resistance
≥ 125 N/50mm | [EN 12317-2] |
Service Temperature
-10 °C min. / +35 °C max
Foldability at Low Temperature
- 30 °C | (EN 1109) |
Water Tightness
Pass (Method B, 24h/60kPa) | Pass (Method B, 24h/60kPa) |
Resistance to lateral water migration
Pass, up to 7 bar | [ASTM D 5385 modified] |
Accelerated Ageing in Alkaline Environment Tensile Strength
Pass (28 d/+23 °C) | (EN 1847) |
Pass (Method B, 24 h / 60 kPa) | (EN 1928) |
Durability of Water Tightness against Chemicals
Pass (28 d/+23 °C) | (EN 1847) |
Pass (Method B, 24 h / 60 kPa) | (EN 1928) |
Durability of Water Thightness against Ageing
Pass (12 weeks) | (EN 1296) |
Pass (Method B, 24 h / 60 kPa) | (EN 1928) |
Reaction to Fire
Class E | [EN 13501-1] |
Application
Ambient Air Temperature
+ 5 °C min. / + 35 °C max.
Dew Point
The substrate temperature must be at least 3°C above the dew point to reduce the risk of condensation and reduced adhesion.
Substrate Temperature
Substrate bonding surface: minimal +5 °C ( Refer to important considerations for more information)
Substrate Moisture Content
≤ 6 % parts by weight. No rising moisture
EQUIPMENT
- Tape measure
- Marking pen
- Razor knife
- Scissors
- Pressure roller
- Clean lint-free cloth
- Metal straight edge for cutting
- Protective sheet for cutting
SUBSTRATE QUALITY
Concrete substrate must be sound and of sufficient compressive strength (minimum 25 N/mm2) with a minimum tensile adhesion strength of 1.5 N/mm2.
Substrate must be even, level, clean, dry and free of all contaminants such as dirt, oil, grease and surface treatments.
Weak cementitious substrates must be removed and surface defects such as blow holes and voids must be fully exposed and repaired accordingly.