SikaProof® P-12
FPO self adhesive sheet membrane for post-applied fully bonded below ground waterproofing
SikaProof® P-12 is a flexible polyolefin (FPO) self-adhesive sheet membrane for post-applied fully bonded below ground waterproofing of existing reinforced concrete structures. Membrane thickness 1,2 mm. SikaProof® P-12 is pre-coated with an adhesive sealant layer and is cold applied onto primed concrete structure by a simple peel and stick process by using SikaProof® Primer-01 as a system primer.
- Post-self-adhered, fully bonded on existing concrete structures
- No lateral water underflow between the concrete structure and the membrane system
- High flexibility and crack-bridging
- Validated high watertightness
- Easy to install with fully adhered joints (no welding required)
- Cold applied (no heat or open flames)
- Temporarily resistant to weathering and UV-light during construction
- Highly durable and resistant to aging
- Resistant to aggressive elements in natural ground water and soil
- Can be combined with other approved Sika Waterproofing / Joint Sealing Systems
![SikaProof® P-12](https://pim2.sika.com/medias/sys_master/root/h84/hfb/8851308118046/02-en-NZ-sikanz-approved-contractor-only-logo-600.png)
Usage
Damp-proofing, waterproofing and concrete protection for basements and other below ground structures against ground water ingress. Suitable for use on:- Horizontal reinforced concrete slabs, decks and podiums
- Vertical reinforced concrete walls
- Extensions and reconstruction works
- Prefabricated structures
Advantages
- Post-self-adhered, fully bonded on existing concrete structures
- No lateral water underflow between the concrete structure and the membrane system
- High flexibility and crack-bridging
- Validated high watertightness
- Easy to install with fully adhered joints (no welding required)
- Cold applied (no heat or open flames)
- Temporarily resistant to weathering and UV-light during construction
- Highly durable and resistant to aging
- Resistant to aggressive elements in natural ground water and soil
- Can be combined with other approved Sika Waterproofing / Joint Sealing Systems
Packaging
Rolls wrapped individually in a yellow PE-film.
Roll width | Roll length |
1,00 m | 20 m |
Colour
Light yellow sheet membrane with a white release film on the adhesive side.
Product Details
ENVIRONMENTAL INFORMATION
BRE Environmental Product Declaration (EPD) available
APPROVALS / STANDARDS
CE Marking and Declaration of Performance to EN 13967 - Flexible sheets for waterproofing – Damp proofing and basement tanking
Agrement Certificate, SikaProof® P,BBA,Certificate No.13-5075
Test Report, Functionality, SikaProof P-12, WISSBAU, No. 2013-253
abP Approval, SikaProof P-12, Report No. MPANRW-2211463-1
Chemical Base
Membrane Layer: | Flexible Polyolefin (FPO) |
Sealant/adhesive: | Polyolefin (PO) |
Shelf Life
12 months from date of production
Storage Conditions
Product must be stored in original unopened and undamaged sealed packaging in dry conditions and temperatures between + 5 °C and + 30 °C. Store in a horizontal position. Do not stack pallets of the rolls on top of each other, or under pallets of any other materials during transport or storage. Always refer to packaging.
Visible Defects
Pass | (EN 1850-2) |
Effective Thickness
Total Thickness (= deff) | 1,20 mm (-5 /+10 %) |
Membrane Thickness | 0,60 mm |
Mass per Unit Area
1,20 kg/m2 | (-5 /+10%) |
System Structure
The following system components must be used:
SikaProof® P-12 sheet membrane
SikaProof® Primer-01
Ancillary products:
Accessories and complementary products are available to provide detailing and connection solutions.
Resistance to Impact
≥ 200mm | Method A |
Resistance to Static Load
≥ 20kg | Method B |
Resistance to Root Penetration
Pass | (CEN/TS 14416) |
Tensile Strength
Machine direction: | ≥ 6,0 N/mm2 |
Cross direction: | ≥ 6,0 N/mm2 |
Elongation
Machine direction: | ≥ 350 % |
Cross direction: | ≥ 350 % |
Resistance to Tearing (nail shank)
Machine direction: | ≥ 200 N |
Cross direction: | ≥ 200 N |
Joint Shear Resistance
≥ 125 N/50mm | (EN 12317-2) |
Crack Bridging Ability
Class A 5, no cracks | (EN 1062-7) |
Foldability at Low Temperature
- 30 °C | (EN 1109) |
Reaction to Fire
Class E | (EN 13501-1) |
Accelerated Ageing in Alkaline Environment Tensile Strength
Pass (28 d/+23 °C) | (EN 1847) |
Pass (Method B, 24 h / 60 kPa) | (EN 1928) |
Water Tightness
Pass (Method B, 24h/60kPa) | (EN 1928) |
Durability of Water Thightness against Ageing
Pass (12 weeks) | (EN 1296) |
Pass (Method B, 24 h / 60 kPa) | (EN 1928) |
Durability of Water Tightness against Chemicals
Pass (28 d/+23 °C) | (EN 1847) |
Pass (Method B, 24 h / 60 kPa) | (EN 1928) |
Service Temperature
-10 °C min. / +35 °C max
Adhesion in Peel
≥ 100 N/50mm (on primed concrete) | (DIN EN 1372) |
Resistance to lateral water migration
Pass, up to 7 bar | (ASTM D5385 / D5385M) |
Application
Ambient Air Temperature
+ 5 °C min. / + 35 °C max.
Dew Point
The substrate temperature must be at least 3°C above the dew point to reduce the risk of condensation and reduced adhesion.
Substrate Temperature
Substrate bonding surface: minimal +5 °C ( Refer to important considerations for more information)
Substrate Moisture Content
≤ 6 % parts by weight. No rising moisture
EQUIPMENT
Tape measure
Marking pen
Razor knife
Scissors
Pressure roller
Clean lint-free cloth
Metal straight edge for cutting
Protective sheet for cutting
SUBSTRATE QUALITY
Concrete substrate must be sound and of sufficient compressive strength (minimum 25 N/mm2) with a minimum tensile adhesion strength of 1,5 N/mm2.
Substrate must be even, level, clean, dry and free of all contaminants such as dirt, oil, grease and surface treatments.
Weak cementitious substrates must be removed and surface defects such as blow holes and voids must be fully exposed and repaired accordingly.
APPLICATION
Substrate preparation
If the substrate does not fulfil the requirements the surface must be pre-treated prior to the application, in order to prevent any subsequent damage to the waterproofing membrane sheets. The use of SikaProof® Primer-01 is required to ensure an optimal, durable bond to the substrate (this primer is a defined system component).
Installation procedure
Strictly follow installation procedures as defined in method statementsand, insatllation or working instructions which must always be adjusted to the actual site conditions.
Installation method - General
After substrate conditions and priming have been fulfilled, the waterproofing membrane is installed by peel & stick method onto horizontal / inclined / vertical hardened concrete substrates. The membrane sheets are overlapped with the following sheet. No heat or open flames are required for installing any part of the membrane system.
T-joints, transitions and corners
All T-joints and transitions must be sealed additionally with a strip or patch of SikaProof® ExTape-150.
Detailing
Form all details and connections using the appropriate SikaProof® ancillary products outlined in the ‘Method Statement - SikaProof® P
Construction and expansion joints
For sealing these types of joints, use additional Sika® Joint Solutions.
Inspection and quality control of installation
A final inspection before protecting and backfilling must be carried out to ensure the complete membrane system has been correctly installed, and any damage repaired.
Backfilling protection
After installation is completed SikaProof® P-12 system must be protected with an appropriate protection sheet as soon as possible or at the latest within 90 days or before backfilling.