Sikafloor®-18 Pronto
Sikafloor®-18 Pronto is a two part, reactive, medium-viscocity, fast curing, flexible seal coat for elastic Sikafloor® car park systems.
- Can bridge cracks to a certain degree
- Good resistance to specific chemicals
- Good mechanical resistance
- Good resistance to UV exposure
- Solvent free
- Very fast curing even at low temperatures
Usage
The product is used as a seal coat for:- Broadcast layers of the Sikafloor® Pronto Modular System
- Broadcast screeds prepared of e.g. Sikafloor®-81 EpoCem® or Sikafloor®-264 N, if broadcast to excess
Advantages
- Can bridge cracks to a certain degree
- Good resistance to specific chemicals
- Good mechanical resistance
- Good resistance to UV exposure
- Solvent free
- Very fast curing even at low temperatures
Packaging
| Container Part A | 25 kg, (25.5L) |
| Container Part B | Sikafloor® Pronto Hardener: 25kg Bags |
| Part C | Sika® Pronto Pigment: 25 kg Bags |
Colour
| Part A | transparent, bluish liquid |
| Part B | white, powder |
| Part C | Sika® Pronto Pigment |
Product Details
APPROVALS / STANDARDS
CE Marking and Declaration of Performance to EN 13813:2002 — Screed material and floor screeds — Synthetic resin screed material
Migration Behaviour EN 1186, EN 13130, CEN/TS 14234, Sikafloor® Pronto, ISEGA, Certificate No. 51188 U 20
Chemical Base
Reactive acrylic resins
Shelf Life
| Part A | 12 months from date of production |
| Part B | 12 months from date of production |
| Part C | 24 months from date of production |
Storage Conditions
The Product must be stored in original, unopened and undamaged sealed packaging in dry conditions at temperatures between +5 °C and +30 °C.
Always refer to packaging.
Refer to the current Safety Data Sheet for information on safe handling and storage.
Density
| Part A | ~0.98 kg/I (+23 °C) |
Solid content by weight
~100 %
Solid content by volume
~100 %
Chemical Resistance
Resistant to many chemicals. Contact Sika technical service for specific information.
Service Temperature
| Short-term, maximum 1 hour | <+80 °C |
| Permanent | <+50 °C |
IMPORTANT
Exposure to moist or wet heat
Sikafloor® broadcast systems with a minimum thickness of ~3–4 mm, that use this product, can resist short-term moist or wet heat of up to +80 °C, if the exposure is only temporary (less than 1 hour). However, during exposure to moist or wet heat, do not also subject the Sikafloor® broadcast system to chemical and/or mechanical strain, as it may cause damage to the system.
Application
Mixing Ratio
Part A : Part C = 9 : 1 (by weight)
The amount of Part B required depends on the substrate temperature:
| Substrate temperature | % by weight (Sikafloor® Pronto Hardener) |
| 0 °C | 6 % |
| +10 °C | 5 % |
| +20 °C | 2 % |
| +30 °C | 1 % |
Note: For ease of handling, units may be split into smaller amounts. Make sure to follow the mixing ratios as described in the Application Information. Always weigh out each part before mixing it.
Product Temperature
Minimum | 0 °C |
Maximum | +30 °C |
Ambient Air Temperature
Minimum | 0 °C |
Maximum | +30 °C |
Relative Air Humidity
80 % r.h. max.
Dew Point
Beware of condensation. The substrate and uncured applied product must be at least +3 °C above dew point to reduce the risk of condensation on the surface of the applied product.
Substrate Temperature
Minimum | 0 °C |
Maximum | +30 °C |
Substrate Moisture Content
Substrate | Method method | Moisture content |
Cementitious substrates | Sika® Tramex moisture metre | ≤ 4% |
Cementitious substrates | Calcium carbide method (CM-method) | ≤ 4 % |
No rising moisture (ASTM D4263, polyethylene sheet)
Pot Life
Product temperature | Time |
0 °C | ~20 minutes |
+10 °C | ~20 minutes |
+20 °C | ~15 minutes |
+30 °C | ~8 minutes |
Note: Times are approximate and will be affected by changing ambient conditions, particularly temperature and relative humidity.
Waiting Time / Overcoating
Before overcoating the Product, allow:
| Substrate temperature | Waiting time |
| 0 °C | ~50 minutes |
| +10 °C | ~50 minutes |
| +20 °C | ~40 minutes |
| +30 °C | ~30 minutes |
Note: Times are approximate and will be affected by changing ambient conditions, particularly temperature and relative humidity.
Applied Product Ready for Use
Temperature | Foot traffic | Full cure |
0 °C | ~50 minutes | ~2 hours |
+10 °C | ~50 minutes | ~2 hours |
+20 °C | ~40 minutes | ~1 hours |
+30 °C | ~30 minutes | ~1 hours |
Note: Times are approximate and will be affected by changing ambient conditions, particularly temperature and relative humidity.
Consumption
| ~0.5–0.8 kg/m² (0.5-0.8L/m2) depending on the system applied in 1 - 2 coats (total max. 0.8 kg/m² (0.8L/m2)) |
Note: These figures are theoretical and do not allow for any additional material due to surface porosity, surface profile, variations in level, wastage or any other variations. Apply product to a test area to calculate the exact consumption for the specific substrate conditions and proposed application equipment.
APPLICATION INSTRUCTIONS
IMPORTANT
Strictly follow installation procedures
Strictly follow installation procedures as defined in Method Statements, application manuals and working instructions which must always be adjusted to the actual site conditions.
EQUIPMENT
APPLICATION EQUIPMENT
-
Short pile roller
-
Squeegee
MIXING EQUIPMENT
-
Explosion-proof electric double paddle mixer (>700 W, 300 to 400 rpm)
MIXING
2-PART PIGMENTED
- Mix Part A (resin) for ~30 seconds.
- Pigment is added at 10% by weight. In a separate container, add 2.5kg (2.5L) of the pigment (Part C) to 2.5kg of resin (Part A), and mix until you've achieved a homogenous premix.
- Add this premix into the remaining Part A and mix for 3 minutes.
- Add the required amount of Part B (refer to Mixing ratio in Application information) to Part A.
- Mix for an additional minute, until a uniform mix is achieved.
- To ensure thorough mixing, pour materials into another container and mix again to achieve a smooth and uniform mix.
- During the final mixing stage, scrape down the sides and bottom of the mixing container with a flat or straight edge trowel at least once to ensure complete mixing.
APPLICATION
IMPORTANT
Protect from moisture
After application, protect the Product from damp, condensation and direct water contact for a minimum of 1 hour.
IMPORTANT
Ventilation in confined spaces
Always ensure good ventilation when applying the Product in a confined space.
IMPORTANT
No application on rising moisture
Do not apply on substrates with rising moisture.
IMPORTANT
Ventilation for curing
For optimal curing, exchange the air at least seven times per hour. During application and curing, use a forced fresh air supply/exhausting of fumes with appropriate equipment (explosion-proof).
IMPORTANT
Remove foodstuff from application area
Reactive acrylic resins exhibit a characteristic odour during application and before achieving full cure. Once fully cured, they are taint free. All unpackaged goods must be removed from the area of the works during application.
- Do not apply in the presence of foodstuffs.
- Isolate any and all foodstuffs, whether packaged or not, from the flooring works during the application process and until the products are fully cured.
IMPORTANT
Excessive layer thickness may cause damage
If the coat thickness is exceeded (more than 0,8 kg/m2), the resin will tend to flake and yellow. If the coat thickness is too low, excessive monomer loss may occur, leading to insufficient hardness or lower water resistance.
- Make sure to follow the consumption as described in Application information.
IMPORTANT
Temporary heating
If temporary heating is required, do not use gas, oil, paraffin or other fossil fuel heaters. These produce large quantities of both carbon dioxide and water vapour, which may adversely affect the finish.
- For heating, use only explosion-proof electric powered warm air blower systems.
IMPORTANT
Ensuring consistent colour matching
For consistent colour matching, make sure the Product in each area is applied from the same batch numbers.
IMPORTANT
Pin holes
If applied on porous substrates during rising temperatures pin holes may occur from rising air.
- Apply during falling temperatures.
SEAL COAT FOR BROADCAST SURFACES
- Pour the mixed Product onto the substrate. Note: The consumption is specified in Application Information.
- Apply the Product evenly over the surface with a squeegee.
- Back roll the surface in two directions at right angles with a fleece roller. Note: Maintain a "wet edge" during application to achieve a seamless finish.
CLEANING OF TOOLS
Clean all tools and application equipment with Sika® Thinner C immediately after use. Hardened material can only be removed mechanically.