SikaTile®-110 Secure Proof
A PREMIUM PERFORMANCE, CLASS III, FIBRE REINFORCED, READY TO USE, WATER-BASED POLYURETHANE WATERPROOFING MEMBRANE DESIGNED FOR UNDER TILE AND STONE APPLICATIONS.
- A premium performance, flexible class III, ready to use, fibre reinforced, water based polyurethane waterproofing membrane designed for internal and external areas including wet areas, balconies, terraces, and non UV exposed above ground external applications.
- SikaTile®-110 Secure Proof is a suitable undertile waterproofing membrane that complies to AS/NZS 4654:2012 and AS 4858:2004.
- Premixed, ready to use
- High extensibility, Class III
- High elongation ≤500%
- Class III flexible performance
- Solvent free, water-based
- Fibre reinforced
- Excellent antifracture properties
- Excellent cure time
- Low VOC
Usage
SikaTile®-110 Secure Proof is suitable for use on walls and floors for both internal and external applications. SikaTile®-110 Secure Proof is suitable for most typical construction substrates such as.- Concrete
- GRC - Glass reinforced concrete
- Cement boards and sheets including Scyon
- Renders and screeds
- Cement coated light weight construction boards
- Plasterboard
- Structural Plywood
- Autoclaved Aerated Concrete (AAC)
Advantages
- Premixed, ready to use
- High extensibility, Class III
- High elongation ≤500%
- Class III flexible performance
- Solvent free, water-based
- Fibre reinforced
- Excellent antifracture properties
- Excellent cure time
- Low VOC
Packaging
15 Litre Pail / 32 Pails per pallet
Colour
Grey
Product Details
APPROVALS / STANDARDS
BRANZ AS/NZS 4858:2004
Test Certificate DC13205-003
Shelf Life
12 months from date of manufacture when stored unopened in elevated, cool, dry location.
Storage Conditions
Store in dry cool conditions out of direct sunlight. Do not allow membrane to freeze.
Volatile organic compound (VOC) content
40g/L (SCAQMD method 304-91)
Shore A Hardness
72
Tensile Strength
2.1MPa
Permeability to Water Vapour
1.55g/m2 / 24 hours
Application
Ambient Air Temperature
5°C to 35°C
Applied Product Ready for Use
Drying Time | |
Ready for 2nd coat | 1-2 hours after 1st coat |
Ready for tiling | 6-8 hours after final coat |
Ready for flood testing | 48 hours |
Return to service | 3+ days |
All measurements are taken at 23ºC and 50% relative humidity. Specifications vary according to site conditions and should be taken as a guide only.
Consumption
Residential Wet Areas: (2 coats required)
The minimum dry film thickness required is 0.6mm for walls and 1.0mm for floors and perimeter skirting.
A 15 Litre pail will cover approximately 16.6m2 of walls or 10m2 of floors.
Commercial Wet Areas & External Applications (2 coats required)
The minimum dry film thickness required is 1.0mm.
A 15 Litre pail will cover approximately 10m2.
EQUIPMENT
- Brush, or short nap roller
- Protective personal equipment
SUBSTRATE QUALITY
- All surfaces must be installed according to manufacturer’s instructions and relevant Australian Standard(s) and be structurally sound, dry, clean and free from movement, oil, grease, wax, curing compounds, release agents and any other loose or contaminating material.
- Prior to application, remove all sharp protrusions, which may pierce the membrane
- Any voids, potholes in the substrate must be appropriately filled up with a high strength mortar refer to Sika Monotop® mortars.
Concrete:
- All new concrete slabs must have a wood float finish and be allowed to cure for at least 6 weeks (refer to priming details for early aged concrete)
- Old concrete must be cleaned with a strong commercial grade detergent or degreaser. Residue must then be thoroughly washed off with clean water. Allow the surface to dry for at least 24 hours
- All laitance and efflorescence must be removed prior to application.
Cement based Renders & Screeds:
- Renders and screeds should have a wood float finish and be allow to cure for 5-7. (refer priming details for green screeds and renders).
Cement Boards and Sheets:
- All boards and sheet shall be installed in accordance with the manufacturer's instructions and be specifically designed for tiling applications.
- Screw and nail heads must be treated with a Sika® Neutral cure silicone or Sika® Fillet Joint.
- All sheet joints, seams, penetrations, and wall floor junctions shall have a Sika® Neutral cure silicone, Sikaflex® Fillet Joint or a suitable Sika® flexible waterproofing bandage.
SUBSTRATE PREPARATION
Substrate Priming Chart
Application | Primer |
General Priming | SikaTile 010 Secure Prime, Sikafloor®-01 Primer,Sika® Primer-11 W+ |
Green screeds or renders | Sika® Damp Stop |
Autoclaved Aerated Concrete | SikaTile 010 Secure Prime |
Existing tiles | Sika® Prep n Prime |
Refer to the primer data sheet for additional information.
Static Cracks - not subject to movement
- Small hairline cracks, up to 1mm wide, may be filled by the first application of SikaTile®-110 Secure Proof
- For cracks / joints wider than 1mm, a joint filler should be applied along the length of the crack prior to the application of SikaTile®-110 Secure Proof
Non Dymanic Cracks - less than 3mm subject to movement
All cracks / joints, irrespective of their width, must be filled firstly with the bond breaker sealant. Then 50mm wide polyethylene / polypropylene tape should be placed over the crack, ensuring it adheres to the surface. Apply the SikaTile®-110 Secure Proof over the tape as per installation instructions.
Bond Breaker:
SikaTile®-110 Secure Proof has high extensibility and is designed for use with a 12 mm bond breaker, a bead of Sika® Neutral cure silicone, Sika® Fillet Joint or a suitable Sika® flexible waterproofing bandage. The sealant applied must be tooled off to form a 12 mm wide bond breaker. A bond breaker must be installed at areas subject to movement, wall/wall junction, wall/floor junction, sheet joints and seams, penetrations and where there is a change in the direction or substrate type.
Falls to Drains
In all wet areas, falls must be provided to the drain outlet. The slope of this fall should be 1:80 – which equates to a 12.5mm fall over 1m. For wet areas, balconies and rooftops, if the existing substrate does not provide the necessary falls, a sand / cement screed needs to be installed. All other wet areas shall have falls of 1:100 as per AS 3740:2021 Wet Area Membranes.
For balconies and external applications, the slope of this fall should be 1:100 – which equates to a 10mm fall over 1m. If the existing substrate does not provide the necessary fall, a sand / cement screed needs to be installed.
CLEANING OF TOOLS
Clean all tools and application equipment immediately after us with water. Once cured, residual material can only be removed mechanically.