SikaBond® T-55 J
SikaBond® T-55 J is a 1-component, elastic wood flooring adhesive with good workability.
- Adhesive can be sanded
- Floor can be walked on / sanded after 12 / 24 hours
- Elastic, footfall-sound dampening properties
- Good elasticity
- Suitable for use with underfloor heating
- Suitable for bonding directly onto old ceramic tiles
- Reduces stress transfer between the wood floor and the substrate
- Low VOC content
Usage
SikaBond® T-55 J is designed for full surface wood floor bonding of solid and engineered wood floors and subfloors.Advantages
- Adhesive can be sanded
- Floor can be walked on / sanded after 12 / 24 hours
- Elastic, footfall-sound dampening properties
- Good elasticity
- Suitable for use with underfloor heating
- Suitable for bonding directly onto old ceramic tiles
- Reduces stress transfer between the wood floor and the substrate
- Low VOC content
Packaging
2 kg foil pack, 9 foil packs per box
Colour
Ochre
Product Details
ENVIRONMENTAL INFORMATION
- LEED® EQc 4.1
- SCAQMD, Rule 1168
- BAAQMD, Reg. 8, Rule 51
Chemical Base
Polyurethane
Shelf Life
SikaBond® T-55 J has a shelf life of 9 months from the date of production, if it is stored properly in undamaged, original, sealed packaging, and if the storage conditions are met.
Storage Conditions
SikaBond® T-55 J shall be stored in dry conditions, protected from direct sunlight and at temperatures between +5 °C and +25 °C.
Density
1.35 kg/l approx. | (ISO 1183-1) |
Shore A Hardness
38 approx. (after 28 days) | (ISO 868) |
Tensile Strength
1.5 N/mm2 approx. | (ISO 37) |
Shear Strength
1.00 N/mm2 approx., 1 mm adhesive thickness | (ISO 17178) |
Service Temperature
+5 °C to +40 °C
Application
Sag Flow
SikaBond® T-55 J spreads very easily whilst maintaining stable trowel marks.
Ambient Air Temperature
+15 °C to +35 °C
Relative Air Humidity
40% to 70%
Substrate Temperature
During laying and until SikaBond® T-55 J has fully cured, the substrate and ambient temperatures shall be between +15 °C and +35 °C where there is no underfloor heating and between +20 °C and +35 °C where there is underfloor heating.
Substrate Moisture Content
Permissible substrate moisture content without underfloor heating:
- 2.5% CM for cement screeds.
- 0.5% CM for anhydrite screeds.
- 3–12% CM for magnetite flooring (depending on the organic content).
Permissible substrate moisture content for use with underfloor heating:
- 1.8% CM for cement screeds.
- 0.3% CM for anhydrite screeds.
- 3–12% CM for magnetite flooring (depending on the organic content).
Note: In regards to moisture content and quality of the substrates, the guidelines of the wood flooring manufacturer as well as standard construction rules must be observed.
Curing Rate
3.0 mm/24 hours approx. (23 °C / 50% r.h.)
Skin Time / Laying Time
60 minutes approx. (23 °C / 50% r.h.)
Consumption
Full Surface Bonding:
- 600−800 g/m2 with notched trowel B3 (TKB Germany) e.g. for lam parquet, mosaic parquet and industrial parquet.
- 700−900 g/m2 with notched trowel B6 (TKB Germany) or SC+ MB (US Standard) e.g. for engineered wood strips and planks, lam and mosaic parquet.
- 800−1000 g/m2 with notched trowel B11 (TKB Germany) or P5 (US Standard) e.g. solid wood, engineered long-strips and panels, industrial parquet, other residential wood floors and paving, and chipboard.
For bonding long or wide boards, or when working on uneven substrates, it may be necessary to use a notched trowel with bigger notches to ensure that a sufficient amount of SikaBond® T-55 J is applied to provide a uniform adhesive surface and prevent hollow sections i.e. without full surface bond.
For substrates primed with Sika® Primer MB, the consumption of SikaBond® T-55 J may be reduced.
APPLICATION INSTRUCTIONS
For the application of SikaBond® T-55 J all standard construction guidelines apply.
For further information, please refer to the Method Statement "Full Surface Bonding".
SUBSTRATE PREPARATION
- The substrate must be clean, dry, sound and homogeneous, free from oils, grease, dust and loose or friable particles. Paint, cement laitance and other poorly adhering contaminants must be removed.
- Concrete and/or cement screeds must be ground and thoroughly cleaned with an industrial vacuum.
- Anhydrite screeds, including flowable anhydrite screeds must be ground and thoroughly cleaned with an industrial vacuum shortly before bonding with the adhesive starts.
- Broadcast mastic asphalt must be primed with Sika® Primer MB. For the instructions for use, please refer to the corresponding Product Data Sheet.
- Glazed ceramic and old existing ceramic tiles must be degreased and cleaned with Sika® Aktivator-205, or the tile surfaces must be ground and then thoroughly cleaned with an industrial vacuum.
- Wood and/or gypsum boards (e.g. chipboard, plywood) must be glued and/or screwed to the substructure to ensure they are properly fixed to the substrate. For floating dry-floors, contact our Technical Service Department.
- For other substrates contact our Technical Service Department for advice and assistance.
- SikaBond® T-55 J can be used without priming on cement based floors, anhydrite floors, chipboards, concrete and ceramic tiles.
- For broadcasted mastic asphalt, cement based floors with excessive moisture content and use over old adhesive residues or on weak substrates use Sika® Primer MB. For detailed instructions contact our Technical Service Department.
CLEANING OF TOOLS
Clean all tools and application equipment immediately after use with Sika® Remover-208. Once cured, residual material can only be removed mechanically.